0901 SPIT STD CONIC TIP CATRPILLAR H63,CATERPILLAR,H63

How to check the valve tip clearances

New 1000 Serie » How to check the valve tip clearances

Four cylinder engines

These are checked between the top of the valve stem and the rocker lever (A), with the engine hot or cold. The correct clearance for inlet valves is 0,20 mm (0.008 in) and 0,45 mm (0.018 in) for exhaust valves. The valve positions are shown at (B).

The sequence of valves from number 1 cylinder is shown in the table below.

Note: Number 1 cylinder is at the front of the engine.

  1. Rotate the crankshaft in the normal direction of rotation until the inlet valve (B7) of number 4 cylinder has just opened and the exhaust valve (B8) of the same cylinder has not closed completely. Check the clearances of the valves (B1 and B2) of number 1 cylinder and adjust them, if necessary.
  2. Set the valves (B3 and B4) of number 2 cylinder as indicated above for number 4 cylinder. Then check / adjust the clearances of the valves (B5 and B6) of number 3 cylinder.
  3. Set the valves (B1 and B2) of number 1 cylinder. Then check / adjust the clearances of the valves (B7 and B8) of number 4 cylinder.
  4. Set the valves (B5 and B6) of number 3 cylinder. Then check / adjust the clearances of the valves (B3 and B4) of number 2 cylinder.



Six cylinder engines

These are checked between the top of the valve stem and the rocker lever (A), with the engine hot or cold. The correct clearance for inlet valves is 0,20 mm (0.008 in) and 0,45 mm (0.018 in) for exhaust valves. The valve positions are shown at (B).

The sequence of valves from number 1 cylinder is shown in the table below.

Note: Number 1 cylinder is at the front of the engine.

  1. Rotate the crankshaft in the normal direction of rotation until the inlet valve (B11) of number 6 cylinder has just opened and the exhaust valve (B12) of the same cylinder has not closed completely. Check the clearances of the valves (B1 and B2) of number 1 cylinder and adjust them, if necessary.
  2. Set the valves (B3 and B4) of number 2 cylinder as indicated above for number 6 cylinder. Then check / adjust the clearances of the valves (B9 and B10) of number 5 cylinder.
  3. Set the valves (B7 and B8) of number 4 cylinder. Then check / adjust the clearances of the valves (B5 and B6) of number 3 cylinder.
  4. Set the valves (B1 and B2) of number 1 cylinder. Then check / adjust the clearances of the valves (B11 and B12) of number 6 cylinder.
  5. Set the valves (B9 and B10) of number 5 cylinder. Then check / adjust the clearances of the valves (B3 and B4) of number 2 cylinder.
  6. Set the valves (B5 and B6) of number 3 cylinder. Then check / adjust the clearances of the valves (B7 and B8) of number 4 cylinder.


Inapoi Seria motor Perkins New 1000 Serie
Noul excavator pe pneuri Komatsu PW148-8 - puternic si versatil O altă noutate pe care producătorul japonez Komatsu o va prezenta este ultimul model de excavator pe pneuri, PW148-8, cu un design compact, cu spatele scurt, pentru a putea fi folosit cu usurintă în santiere cu spatiu limitat de manevră sau pe st
mai multe detalii ...
H63, 0901 SPIT STD CONIC TIP CATRPILLAR H63, CATERPILLAR
Volvo Construction Equipment a prezentat o serie de produse si initiative dedicate extinderii operatiunilor si bazei de clienti in Asia.Astfel, in China, a fost inaugurat de curand Centrul de Tehnologie Volvo din Jinan, a fost extinsa capacitatea de productie a fabricii Volvo din Linyi, iar incepand cu 2003 s-au facut
mai multe detalii ...
CATERPILLAR, 0901 SPIT STD CONIC TIP CATRPILLAR H63, H63

Sediu : 700045 Iasi, Strada Sfantul Lazar nr. 27, Kapital Invest Building -  etajul 2
Depozit :
700382 Iasi,Str. Aurel Vlaicu 88
600343 Bacau,Str. Letea 32
062202 Bucuresti, Str. Preciziei 32
2059 Chisinau, Str. Petricani 19/4

Societate aflata in insolventa prin hotararea Tribunalului Iasi din 21 martie 2025, dosar nr. 1116/99/2025

Telefon Romania:

+40 743 122 261
office@commatech.ro