Perkins, 4.236, Documentatie tehnica, Engine fluids

How to check the specific gravity of the coolant

New 1000 Serie » How to check the specific gravity of the coolant

Warning! Do not drain the coolant while the engine is still hot and the system is under pressure because dangerous hot coolant can be discharged.

For mixtures which contain inhibited ethylene glycol:

  1. Ensure that the machine is on level ground.
  2. Operate the engine until it is warm enough to open the thermostat. Continue to run the engine until the coolant has circulated the cooling system.
  3. Stop the engine.
  4. Allow the engine to cool until the temperature of the coolant is below 60 °C (140 °F).
  5. Remove the filler cap of the cooling system.
  6. Drain some coolant from the cooling system into a suitable container.
  7. Use a special coolant hydrometer that will check the temperature and the specific gravity of the coolant, follow the manufacturer's instructions.

    Note: If a special coolant hydrometer is not available, put a hydrometer and a separate thermometer into the antifreeze mixture and check the readings on both instruments. Compare the readings with the chart (A).

  8. Adjust the strength of the mixture as necessary.
  9. Note: If it is necessary to fill or replenish the coolant system in service, mix the coolant to the correct strength before it is added to the coolant system. Perkins POWERPART antifreeze with a concentration of 50% will give protection against frost to a temperature of -35 oC (-31 oF). It will also give protection against corrosion. This is especially important when there are aluminium components in the coolant system.


Inapoi Seria motor Perkins New 1000 Serie
Mai jos sunt cateva sfaturi de baza si cateva indicii pentru a va putea scoate din impas. Cand lucrurile nu merg cum trebuie. Probleme externe Doar pentru ca reductia finala se misca greu sau nu se misca nu inseamna neaparat ca este din
mai multe detalii ...
Engine fluids, 4.236, Documentatie tehnica, Perkins
Constructorul american Case Construction Equipment a dezvăluit câteva dintre noile utilaje si accesorii ce vor fi prezentate publicului cu ocazia celei de-a 29-a editii a celei mai importante expozitii din domeniul constructiilor, care va avea loc în perioada 19 - 25 aprilie a.c. La Bauma vizitatorii stand
mai multe detalii ...
Engine fluids, Documentatie tehnica, Perkins, 4.236

Sediu : 700045 Iasi, Strada Sfantul Lazar nr. 27, Kapital Invest Building -  etajul 2
Depozit :
700382 Iasi,Str. Aurel Vlaicu 88
600343 Bacau,Str. Letea 32
062202 Bucuresti, Str. Preciziei 32
2059 Chisinau, Str. Petricani 19/4

Societate aflata in insolventa prin hotararea Tribunalului Iasi din 21 martie 2025, dosar nr. 1116/99/2025

Telefon Romania:

+40 743 122 261
office@commatech.ro