Senile Otel,HYUNDAI,Excavator,R420

How to clean the integral closed breather system

1000 series » How to clean the integral closed breather system

Caution: Do not use excessive force to remove the hose (A4) from the breather outlet pipe.

Note: The procedure below refers only to the closed breather shown in (A).

  1. Release the hose clip and carefully remove the hose from the breather outlet.
  2. Remove the rocker cover.
  3. Caution: Ensure that the lever does not damage the cover.

  4. Release the fasteners and carefully remove the breather cover from the breather body. A suitable lever may be necessary to release the cover from the body of the breather. Ensure that the lever does not damage the cover. Discard the joint (A5).
  5. Caution: Do not clean the breather valve or the gauze filter. The breather valve (A1) and the gauze (A3) must be renewed every 4000 hours.

  6. Release the clips (A2) from the clip retainers (A7) and push the breather valve out of the breather cover.Discard the breather valve.
  7. Remove and discard the gauze.
  8. Warning! Do not allow compressed air to contact your skin. If compressed air enters your skin, obtain medical help immediately.

  9. Wash the body of the breather, the cover, the baffle plates (A6) and the breather pipe, every 2000 hours of operation. Use an approved kerosene cleaning fluid and dry them with compressed air at low pressure.
  10. Ensure that the holes at the bottom of the baffle plates in the breather body are not restricted. If necessary, clean the holes.

To assemble

  1. Fit the baffle plates into the grooves in the breather body.
  2. Renew and fit the gauze filter into the breather body.
  3. Renew and fit the new valve into the breather cover. Ensure that the clips are engaged correctly.
  4. Note: The breather valve is renewed every 4000 hours.

  5. Renew the joint, which is fitted dry. Put the cover and valve assembly into position on the breather body. Loosely fit the fasteners. Tighten the fasteners gradually and evenly to 3 Nm (2.2 lbf ft) 0.3 kgf m.
  6. Caution: Do not use excessive force to fit the hose to the breather outlet pipe.

  7. Check that there is no restriction in the breather pipe or the breather hose. Fit the breather hose to the cover and tighten the clip.
Inapoi Seria motor Perkins 1000 series
Producatorul Case a prezentat in 2014 la salonul Conexpo noul model de incarcator frontal pe pneuri numit Case 921F. Noul incarcator se bucura de un randament energetic mai bun si este mai performant decat modelele precedente.Echipat cu un motor de 6.7 litri care dezvolta o putere de 168 kW este echipat cu tehnologia S
mai multe detalii ...
R420, Excavator, Senile Otel, HYUNDAI
Piesele pentru motoarele  PERKINS sunt proiectate sa functioneze impreuna pentru a maximiza durata de viata a componentelor si performantele motorului. Piesele PERKINS sunt proiectate pentru a se potrivi caracteristicilor individuale fiecarui motor. Piesele PERKINS redau puterea optima si sunt sust
mai multe detalii ...
HYUNDAI, R420, Excavator, Senile Otel

Sediu : 700045 Iasi, Strada Sfantul Lazar nr. 27, Kapital Invest Building -  etajul 2
Depozit :
700382 Iasi,Str. Aurel Vlaicu 88
600343 Bacau,Str. Letea 32
062202 Bucuresti, Str. Preciziei 32
2059 Chisinau, Str. Petricani 19/4

Societate aflata in insolventa prin hotararea Tribunalului Iasi din 21 martie 2025, dosar nr. 1116/99/2025

Telefon Romania:

+40 743 122 261
office@commatech.ro