Perkins, 3.152, Documentatie tehnica,

How to clean the gauze strainer of the fuel lift pump

1000 series » How to clean the gauze strainer of the fuel lift pump

  1. Release the fastener (A2) and remove the cover and the joint (A3) from the top of the fuel lift pump (A4). Remove the gauze strainer (A1). On some turbocharged engines, it will be necessary to remove the small heat shield which is fitted above the pump.
  2. Wash carefully all of the sediment from the lift pump body.
  3. Clean the gauze strainer, the joint and the cover.
  4. Assemble the lift pump. Use a good joint and ensure that the lift pump body and the cover are fitted together correctly because leakage at this point will let air into the fuel system. Fit the heat shield, if one is fitted.
  5. Eliminate the air from the fuel system through the filter vent plug.
Inapoi Seria motor Perkins 1000 series
Excavator pentru demolări, modelul PC290LC/NLC-8 HRD. Va fi cel mai mic model de excavator pentru demolări din această gamă de utilaje. Noul PC290LC/NLC-8 HRD are o greutate proprie de 40 tone (incluzând atasamentul de lucru) si are o înăltime de lucru de 18,3 m, fiind utilajul perfect pentru activită
mai multe detalii ...
3.152, Perkins, Documentatie tehnica,
KOMATSU a prezentat la Intermat 2015 noul incarcator pe pneuri WA270-7, care inlocuieste modelul WA250PZ-6.Cu noua motorizare SAA6D107E-2, incarcatorul realizeaza o economie de consum de 10% in raport cu modelul precedent, totodata aducand un plus de putere si un confort sporit de utilizare, dezvoltand o putere neta de
mai multe detalii ...
Documentatie tehnica, Perkins, , 3.152

Sediu : 700045 Iasi, Strada Sfantul Lazar nr. 27, Kapital Invest Building -  etajul 2
Depozit :
700382 Iasi,Str. Aurel Vlaicu 88
600343 Bacau,Str. Letea 32
062202 Bucuresti, Str. Preciziei 32
2059 Chisinau, Str. Petricani 19/4

Societate aflata in insolventa prin hotararea Tribunalului Iasi din 21 martie 2025, dosar nr. 1116/99/2025

Telefon Romania:

+40 743 122 261
office@commatech.ro