A new fuel lift pump (A), has been introduced for use on four cylinder New 1000 Series. The new pump is a one-piece assembly and should not be dismantled. A strainer (B1) is fitted inside the fuel inlet connection (B3). This strainer is cleaned at the same service interval as the strainer fitted to other fuel lift pumps. The procedure to remove and to fit this fuel lift pump is as the earlier fuel lift pumps.
A kit, is available that provides a fuel lift pump and a joint.
To clean the strainer
Caution: Ensure that the olive on the fuel inlet pipe is in good condition. If it is not, renew the olive or the pipe.
If there is not a good seal, air will enter the fuel system when the engine is run.