Caution: The material used for the cover, fitted to the engine breathers has been changed to a harder plastic.
As a result, the maintenance procedure and the maintenance period have changed. Also the part number has changed from 4133J005 to 4133J008. The part number is marked on the top of the cover of the latest oil separator. Do not try to remove the cover of the oil separator as it will break. The whole oil separator should be renewed at every engine overhaul or 8000 hours.
Some engines are fitted with an open breather which has a steel gauze (A2) to separate the oil from the crankcase gases before they leave the engine.
Note: It is not necessary to remove the body of the breather from the rocker cover to obtain access to the gauze.

Caution: It is very important that closed circuit breather systems are fitted correctly to the engine. Incorrect installation can cause extreme damage to the engine.
Below is a series of safety precautions that must be applied at all times.
The closed circuit breather used on the New 1000 Series engine comprises a body (A4) and a valve assembly (A5). The whole assembly must be renewed every complete overhaul of the engine or 8000 hours.