Perkins, New 1000 Serie, Техническая документация, Engine preservation

Air cleaner

New 1000 Serie » Air cleaner

Caution: Do not use gasoline to clean the air cleaner.

A typical wet type air cleaner is shown at (A). The wet type air cleaner must be drained at a suitable interval. The container and element (A1) must be cleaned with kerosene or with another suitable fluid. Do not use gasoline. Check that the seal (A3) is not damaged and renew it, if necessary. Fill to the indicated level (A2) with clean engine lubricating oil.

Restriction indicator

The restriction indicator for these engines must work at a pressure difference of 508/558 mm (20/22 in) of water gauge. It is fitted on the air filter outlet or between the air filter and the induction manifold. When the red warning indicator (C1) is seen through the clear panel (C2) after the engine has stopped, the air filter element must be removed for service. After a clean element has been fitted, press the rubber bottom (C3) or the button (C4) of the restriction indicator to reset the red warning indicator.