Perkins, 1000 series, Technical features, General information

How to clean the integral closed breather system

1000 series » How to clean the integral closed breather system

Caution: Do not use excessive force to remove the hose (A4) from the breather outlet pipe.

Note: The procedure below refers only to the closed breather shown in (A).

  1. Release the hose clip and carefully remove the hose from the breather outlet.
  2. Remove the rocker cover.
  3. Caution: Ensure that the lever does not damage the cover.

  4. Release the fasteners and carefully remove the breather cover from the breather body. A suitable lever may be necessary to release the cover from the body of the breather. Ensure that the lever does not damage the cover. Discard the joint (A5).
  5. Caution: Do not clean the breather valve or the gauze filter. The breather valve (A1) and the gauze (A3) must be renewed every 4000 hours.

  6. Release the clips (A2) from the clip retainers (A7) and push the breather valve out of the breather cover.Discard the breather valve.
  7. Remove and discard the gauze.
  8. Warning! Do not allow compressed air to contact your skin. If compressed air enters your skin, obtain medical help immediately.

  9. Wash the body of the breather, the cover, the baffle plates (A6) and the breather pipe, every 2000 hours of operation. Use an approved kerosene cleaning fluid and dry them with compressed air at low pressure.
  10. Ensure that the holes at the bottom of the baffle plates in the breather body are not restricted. If necessary, clean the holes.

To assemble

  1. Fit the baffle plates into the grooves in the breather body.
  2. Renew and fit the gauze filter into the breather body.
  3. Renew and fit the new valve into the breather cover. Ensure that the clips are engaged correctly.
  4. Note: The breather valve is renewed every 4000 hours.

  5. Renew the joint, which is fitted dry. Put the cover and valve assembly into position on the breather body. Loosely fit the fasteners. Tighten the fasteners gradually and evenly to 3 Nm (2.2 lbf ft) 0.3 kgf m.
  6. Caution: Do not use excessive force to fit the hose to the breather outlet pipe.

  7. Check that there is no restriction in the breather pipe or the breather hose. Fit the breather hose to the cover and tighten the clip.
Back Perkins engine series 1000 series
more details ...
Technical features, 1000 series, Perkins, General information
more details ...
Technical features, 1000 series, General information, Perkins

Headquarters : 700045 Iasi, 27 Sfantul Lazar Street, Kapital Invest Building -  2nd Floor
Warehouse :
700382 Iasi,88 Aurel Vlaicu Street
600343 Bacau, 32 Letea Street
062202 Bucuresti, 32 Preciziei Street
2059 Chisinau, 19/4 Petricani Street

Societate aflata in insolventa prin hotararea Tribunalului Iasi din 21 martie 2025, dosar nr. 1116/99/2025

Phone Romania:

+40 743 122 261
office@commatech.ro